{"created":"2023-05-15T14:42:20.352055+00:00","id":2591,"links":{},"metadata":{"_buckets":{"deposit":"111ab1a5-74d8-4ac3-be24-98107499a2ea"},"_deposit":{"created_by":3,"id":"2591","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2591"},"status":"published"},"_oai":{"id":"oai:ksu.repo.nii.ac.jp:00002591","sets":["14:179:186"]},"author_link":["6845","20080","20082","20985"],"control_number":"2591","item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"123","bibliographicPageStart":"115","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"京都産業大学先端科学技術研究所所報"},{"bibliographic_title":"The bulletin of the Research Institute of Advanced Technology Kyoto Sangyo University","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The importance of the information concerning the depth of interaction (DOI) in a PET device has been stressed by many authors. In this paper, the attenuation of the emitted light in a thin LYSO (Ce) scintillator crystal has been measured for the purpose of obtaining information about DOI from the ratio of the light output measured at both ends of the crystal. A pair of photomultipliers were attached to the two ends of the crystal for this purpose. An array of wave-length shifters(WLS) attached to the crystal from a side was used in order to find the hit point of the incident gamma rays along the crystal. The attenuation constant μ determined in this measurement is μ=0.79 ± 0.0007/cm. This value is experimentally demonstrated to be appropriate for the DOI estimation using the ratio of the amounts of light. The obtainable DOI resolution, when the crystal is read out using WLS and a new kind of position-sensitive photomultipliers in our next prototype, is estimated.","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"4","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00005048660","subitem_description_type":"Other"}]},"item_2_description_2":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"研究論文","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Paper","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA11815191","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1347-3980","subitem_source_identifier_type":"PISSN"}]},"item_2_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Information and Communication Sciences, Kyoto Sangyo University"},{"subitem_text_language":"en","subitem_text_value":"Department of Information and Communication Sciences, Kyoto Sangyo University"},{"subitem_text_language":"en","subitem_text_value":"Department of Information and Communication Sciences, Kyoto Sangyo University"},{"subitem_text_language":"en","subitem_text_value":"Faculty of Science, Kyoto Sangyo University"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"AOGAKI, Souichirou","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KOTAKA, Hideki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MORITANI, Ikuo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TAKEUCHI, Fujio","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-01-28"}],"displaytype":"detail","filename":"KJ00005048660.pdf","filesize":[{"value":"244.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00005048660.pdf","url":"https://ksu.repo.nii.ac.jp/record/2591/files/KJ00005048660.pdf"},"version_id":"9255f809-8a81-42e4-9f54-467bdd5496a7"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Depth of interaction measured with LYSO (Ce) scintillator in a new method","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Depth of interaction measured with LYSO (Ce) scintillator in a new method","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["186"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-01-28"},"publish_date":"2018-01-28","publish_status":"0","recid":"2591","relation_version_is_last":true,"title":["Depth of interaction measured with LYSO (Ce) scintillator in a new method"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-09-28T05:56:53.946402+00:00"}