WEKO3
アイテム
Depth of interaction measured with LYSO (Ce) scintillator in a new method
http://hdl.handle.net/10965/00002582
http://hdl.handle.net/10965/000025829474a153-261a-4b41-8264-4ef81438da17
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | [ELS]紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-01-28 | |||||
タイトル | ||||||
タイトル | Depth of interaction measured with LYSO (Ce) scintillator in a new method | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11815191 | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P | |||||
著者 |
AOGAKI, Souichirou
× AOGAKI, Souichirou× KOTAKA, Hideki× MORITANI, Ikuo× TAKEUCHI, Fujio |
|||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Department of Information and Communication Sciences, Kyoto Sangyo University | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Department of Information and Communication Sciences, Kyoto Sangyo University | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Department of Information and Communication Sciences, Kyoto Sangyo University | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Faculty of Science, Kyoto Sangyo University | |||||
記事種別(日) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 研究論文 | |||||
記事種別(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Paper | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The importance of the information concerning the depth of interaction (DOI) in a PET device has been stressed by many authors. In this paper, the attenuation of the emitted light in a thin LYSO (Ce) scintillator crystal has been measured for the purpose of obtaining information about DOI from the ratio of the light output measured at both ends of the crystal. A pair of photomultipliers were attached to the two ends of the crystal for this purpose. An array of wave-length shifters(WLS) attached to the crystal from a side was used in order to find the hit point of the incident gamma rays along the crystal. The attenuation constant μ determined in this measurement is μ=0.79 ± 0.0007/cm. This value is experimentally demonstrated to be appropriate for the DOI estimation using the ratio of the amounts of light. The obtainable DOI resolution, when the crystal is read out using WLS and a new kind of position-sensitive photomultipliers in our next prototype, is estimated. | |||||
書誌情報 |
京都産業大学先端科学技術研究所所報 en : The bulletin of the Research Institute of Advanced Technology Kyoto Sangyo University 巻 7, p. 115-123, 発行日 2008-07 |
|||||
表示順 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 4 | |||||
アクセション番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | KJ00005048660 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1347-3980 |